Reynolds number calculator for pipe flow
Re for water at 20 °C in a 50 mm pipe at 1.5 m/s, and the speed below which the flow stays laminar.
Free. You get your own copy of this worksheet to change and extend (sign-in required).
Short answer
How do you calculate the Reynolds number for flow in a pipe?
Re = ρ·v·D / μ. Water at 20 °C (ρ = 998 kg/m³, μ = 1.002 mPa·s) flowing at 1.5 m/s in a 50 mm bore pipe has Re ≈ 74,700, well into turbulent flow. Pipe flow is laminar below about Re = 2,300, which in this pipe means slower than 0.046 m/s. Between 2,300 and roughly 4,000 the flow is transitional.
The worksheet
Every value below is the output of the Calcanvas compute engine for exactly these cells, evaluated top to bottom. Variables carry their units from one cell to the next.
1. Fluid and pipe
Density and dynamic viscosity of water at 20 °C, the pipe bore and the mean velocity.
rho = 998 kg/m^3mu = 1.002e-3 Pa*sD = 50 mmv = 1.5 m/s2. Reynolds number
Every unit cancels, so Re comes out as a plain number. If units are left over, an input is wrong; that is the dimension check doing its job.
Re = rho*v*D/munu = (mu/rho).to(mm^2/s)3. Where laminar flow ends
Solving Re = 2300 for the velocity gives the fastest flow that stays laminar in this pipe.
vlam = (2300*mu/(rho*D)).to(m/s)reyn(u) = rho*u*D/muus = (0.05, 0.1 .. 2) * m/sMake it yours
Open this example as a board and try a few changes. Results update as you type:
- Try a light oil: rho = 870 kg/m^3 and mu = 0.1 Pa*s.
- Enter the flow rate instead: v = (2 L/s) / (pi*D^2/4).
- Feed Re into the pipe pressure drop example to pick a friction factor.
More examples
- Pipe pressure drop calculator (Darcy–Weisbach) — Reynolds number, Blasius friction factor, Darcy–Weisbach pressure drop and head loss for water in a 50 mm pipe.
- LMTD heat exchanger calculator — Duty, LMTD and required area for a counterflow water-to-water exchanger, with area against U.
- Engineering unit conversions — Length, speed, power, pressure, volume, energy and force conversions — plus the error you get for mismatched units.