Pipe pressure drop calculator (Darcy–Weisbach)
Reynolds number, Blasius friction factor, Darcy–Weisbach pressure drop and head loss for water in a 50 mm pipe.
Free. You get your own copy of this worksheet to change and extend (sign-in required).
Short answer
How do you calculate the pressure drop in a pipe?
The Darcy–Weisbach equation gives the pressure drop as Δp = f · (L/D) · ρv²/2. For water at 2 m/s in a 30 m run of 50 mm pipe, Re ≈ 99,800, the Blasius friction factor is f = 0.0178, and the pressure drop is 21.3 kPa — a head loss of 2.17 m at a flow of 3.93 L/s.
The worksheet
Every value below is the output of the Calcanvas compute engine for exactly these cells, evaluated top to bottom. Variables carry their units from one cell to the next.
1. Fluid and pipe
Water at about 20 °C, flowing at 2 m/s through 30 m of 50 mm bore pipe.
rho = 998 kg/m^3mu = 1.0e-3 Pa*sD = 50 mmv = 2 m/slen = 30 mg = 9.81 m/s^22. Reynolds number and friction factor
The mixed mm and m units cancel to a pure number. Blasius (f = 0.316 / Re^0.25) holds for smooth pipes up to Re ≈ 10⁵.
Re = rho*v*D / muf = 0.316 / Re^0.253. Pressure drop, head loss and flow
Darcy–Weisbach in kPa, the same loss as metres of water, and the volumetric flow in litres per second.
dp = (f * len/D * rho*v^2/2).to(kPa)hf = (dp / (rho*g)).to(m)Q = (pi*D^2/4 * v).to(L/s)Make it yours
Open this example as a board and try a few changes. Results update as you type:
- Halve the diameter to 25 mm and see how fast the loss grows.
- Change len to 100 ft — mixed unit systems are fine.
- Read the pressure drop in psi with dp.to(psi).
More examples
- Engineering unit conversions — Length, speed, power, pressure, volume, energy and force conversions — plus the error you get for mismatched units.
- Heat loss through a wall (U-value) calculator — Heat flow through 12 m² of wall at U = 0.3 W/m²K and a 20 K temperature difference, in watts and kWh.
- Cantilever beam deflection calculator — Tip deflection, fixed-end moment and the full deflection curve of a cantilever with an end point load.