Energy to heat water calculator
Energy, heating time and cost to take a 150 L tank from 10 °C to 55 °C with a 3 kW element.
Free. You get your own copy of this worksheet to change and extend (sign-in required).
Short answer
How much energy does it take to heat water?
The energy is Q = m × c × ΔT, with c = 4,186 J/(kg·K) for water. Taking 150 L from 10 °C to 55 °C is a 45 K rise and needs 7.85 kWh. A 3 kW element does it in about 157 minutes if no heat escapes, and at 0.30 per kWh the energy costs about 2.35.
The worksheet
Every value below is the output of the Calcanvas compute engine for exactly these cells, evaluated top to bottom. Variables carry their units from one cell to the next.
1. Water
A litre of water weighs about a kilogram. The specific heat is per kilogram per kelvin.
vol = 150 literrho_w = 1 kg/litermass_w = vol*rho_wc_w = 4186 J/(kg*K)2. Energy for the rise
From 10 °C to 55 °C is a rise of 45 K (a step of one kelvin is a step of one degree Celsius). Joules convert straight to kWh.
dT = 45 KQ_heat = (mass_w*c_w*dT).to(kWh)3. Time and cost
Divide by the element's power for the time. The price is per kWh, so the cost comes out as a plain number in your currency.
heater = 3 kWt_heat = (Q_heat/heater).to(min)price = 0.30 / kWhcost = Q_heat*priceMake it yours
Open this example as a board and try a few changes. Results update as you type:
- Set dT = 30 K for warmer inlet water in summer.
- Try heater = 2 kW.
- Boil a kettle: vol = 1.7 liter, dT = 80 K, heater = 2.2 kW, then t_heat.to(s).
More examples
- Heat loss through a wall (U-value) calculator — Heat flow through 12 m² of wall at U = 0.3 W/m²K and a 20 K temperature difference, in watts and kWh.
- LMTD heat exchanger calculator — Duty, LMTD and required area for a counterflow water-to-water exchanger, with area against U.
- Thermal expansion calculator — Growth of a 25 m steel pipe heated by 40 K, the stress and force if it is held, and the same pipe in aluminium.