Euler column buckling calculator

Critical load, buckling stress and slenderness of a 3 m pin-ended steel hollow section, plus Pcr against length.

Free. You get your own copy of this worksheet to change and extend (sign-in required).

Short answer

How do you calculate the critical buckling load of a column?

Euler's critical load for a column is Pcr = π²·E·I / (K·L)², where K is the effective length factor (1.0 for pinned ends). A 3 m pin-ended 100×100×5 steel square hollow section (I = 271 cm⁴, A = 18.7 cm²) has Pcr = 594 kN, a stress of 318 N/mm². Its slenderness K·L/r is 78.8, close to the 74.6 at which Euler's stress equals a 355 N/mm² yield, so a real column fails well below Pcr. Design codes such as Eurocode 3 and AISC 360 apply buckling curves for this.

The worksheet

Every value below is the output of the Calcanvas compute engine for exactly these cells, evaluated top to bottom. Variables carry their units from one cell to the next.

1. Section and length

Properties of a 100×100×5 square hollow section. Kf is the effective length factor: 1.0 pinned at both ends, 0.5 fixed at both ends, 2.0 for a free-standing post.

ƒx
E = 200000 N/mm^2= 200000 N/mm²
ƒx
I = 2.71e6 mm^4= 2710000 mm⁴
ƒx
Ag = 1870 mm^2= 1870 mm²
ƒx
Lc = 3 m= 3 m
ƒx
Kf = 1.0= 1

2. Critical load and stress

π²EI over a length squared is a force; dividing by the area gives the stress at which the column buckles.

ƒx
Pcr = (pi^2*E*I / (Kf*Lc)^2).to(kN)= 594.37 kN
ƒx
scr = (Pcr/Ag).to(N/mm^2)= 317.845 N/mm²

3. Does Euler apply?

The radius of gyration r = √(I/A) gives the slenderness K·L/r. Euler's formula only holds for slender columns: above π·√(E/fy), where its stress stays below yield. Near that limit, imperfections and residual stress cut the real capacity a lot.

ƒx
r = sqrt(I/Ag).to(mm)= 38.0683 mm
ƒx
slender = Kf*Lc/r= 78.8057
ƒx
fy = 355 N/mm^2= 355 N/mm²
ƒx
lim = pi*sqrt(E/fy)= 74.5677

4. Critical load against length

Pcr falls with the square of the length: double the length and the column carries a quarter of the load.

ƒx
pcr(len) = (pi^2*E*I / (Kf*len)^2).to(kN)= pcr(len)
ƒx
lens = (1, 1.25 .. 6) * m= [1 m, 1.25 m, 1.5 m, 1.75 m, 2 m, 2.25 m, 2.5 m, 2.75 m, …]
📈 Critical load against length
020004000123456lens (m)kN
pcr(lens) — Euler critical load (kN) against effective length (m).

Make it yours

Open this example as a board and try a few changes. Results update as you type:

  • Set Kf = 0.7 for a column fixed at one end and pinned at the other.
  • Try a 5 m column: slender rises above 130 and Euler is a fair estimate.
  • Change E to 70000 N/mm^2 and fy to 250 N/mm^2 for an aluminium tube.

More examples

Start your first worksheet

Free during early access, no credit card. Open a canvas and watch your math add up in the right units.